Day two of an outage, and the street sounds different. One neighbor’s generator hums quietly by the fence; another’s roars from the driveway all night. Both keep a fridge cold. The difference is inverter vs conventional generator, and it decides how loud your nights are, how much gas you haul, what you can safely plug in and how much power you get for your money.

The verdict: an inverter generator is quieter, uses less fuel at light loads and makes clean power (makers state under 3% THD) for electronics. A conventional (open-frame) generator gives you about twice the watts for the same money and usually a 240-volt outlet for a transfer switch. For essentials, buy an inverter; for a well pump or many circuits, buy conventional.
Inverter vs conventional: side by side
The fairest comparison we found is one brand at one price. Westinghouse lists both of these at $1,299 on its own store (shown unavailable to buy there in October 2026), and both have its CO Sensor shut-off.
| Maker spec | Westinghouse iGen5000DFc (inverter) | Westinghouse WGen7500DFc (conventional) |
|---|---|---|
| Running / starting watts (gas) | 3,900 / 5,000 W | 7,500 / 9,500 W |
| Total harmonic distortion | ≤3% | ≤23% |
| Noise | As low as 52 dB(A) | 72 dB(A) |
| Fuel tank | 3.4 gal | 6.6 gal |
| Runtime at 25% load (gas) | Up to 18 h | Up to 11 h |
| Weight | 105.8 lb | 202.1 lb |
| 240-volt outlet | Only with the optional parallel kit | Yes, L14-30R |
| List price | $1,299 | $1,299 |
Same money: the conventional model gives you nearly twice the watts and a 240-volt outlet, while the inverter is clean, quieter and runs much longer on each gallon at light loads. The sections below go through each difference.
How each one works
A conventional generator spins its alternator directly. To make 60-hertz power, Honda explains, a traditional generator has to run at 3,600 rpm, all the time, whether you’re powering one lamp or the whole load.
An inverter generator makes raw power, turns it into direct current, then uses electronics to build a fresh 60-hertz wave. Because the electronics set the frequency, the engine can slow down when the load is light. Honda calls this Eco Throttle and says it cuts fuel use by up to 40%; Champion calls it Economy Mode and Westinghouse lists an Economy Mode too. Honda says its inverter power is “closer to line power” than any other generator design.
Clean power and THD
Total harmonic distortion (THD) measures how far the voltage wave strays from a smooth sine wave. Lower is cleaner. Here is what the makers themselves state:
- Inverters: Westinghouse iGen2200c and iGen5000DFc ≤3%; Champion’s inverters, including the 4500W dual fuel, under 3%; DuroMax XP2300iH under 3%. Generac describes the GP3300i’s TruePower as “clean, stable power ideal for sensitive electronics” without giving a number.
- Conventional: Westinghouse WGen7500DFc and WGen9500DFc ≤23%. Most open-frame spec pages we read (Champion’s tri fuel models, DuroMax XP13000EH, Generac GP8000E) give no THD figure. Some large conventional models do better: Generac rates its GP15500EFI’s TruePower at under 5%.
For scale, IEEE 519, the recommended practice for power systems, sets 8% voltage THD as the limit for systems at 1 kV and below. Makers say their under-3% inverters are safe for laptops, phones and TVs. Many household appliances now have circuit boards too, from furnace controls to variable-speed fridges, so if an appliance’s manual lists power-quality limits, follow them. When a conventional maker doesn’t publish THD, assume it is not built for sensitive electronics, and use a battery or UPS between it and your computer.
Noise
Noise is where inverters win most clearly. Champion measures both types at 23 feet: its 4500W inverter is rated 61 dB(A), which Champion compares to normal speech, and its 9200W tri fuel open-frame is 74 dB(A), which it says is a bit louder than a vacuum. According to the NIH’s National Institute on Deafness and Other Communication Disorders, every 10 dB seems about twice as loud, so 13 dB is more than twice as loud to your ears. Honda’s EU2200i is rated 48 dB(A) at a quarter load, measured at 23 feet on its spec sheet.
Be careful comparing brands: Westinghouse and DuroMax publish no distance with their figures, and “as low as” means the quietest setting. Generac publishes no dB figure for its portables. Neighbors, HOA rules and local noise limits often matter more at night than the specs.
Fuel use
Makers only publish runtime at set loads, so here is the math from their numbers for the lightest load they list (25%):
| Model | Load at 25% | Maker runtime | Gallons per hour (our math) | kWh per gallon (our math) |
|---|---|---|---|---|
| Champion 4500W inverter | 875 W | 14 h on 2.3 gal | 0.16 | 5.3 |
| Westinghouse iGen5000DFc (inverter) | 975 W | 18 h on 3.4 gal | 0.19 | 5.2 |
| Westinghouse WGen7500DFc | 1,875 W | 11 h on 6.6 gal | 0.60 | 3.1 |
| DuroMax XP13000EH | 2,625 W | 17 h on 8.3 gal | 0.49 | 5.4 |
Two honest takeaways. First, what matters in an outage is gallons per hour at your load. If your essentials average around 1,000 watts once the fridge and pump are cycling (a common situation, but measure yours), then at that load the inverters above burn roughly 0.16 to 0.19 gallons an hour, about 4 to 4.5 gallons a day. No maker publishes a 1,000-watt figure for the big conventional models, but their engines still turn at 3,600 rpm, so expect noticeably more. Second, a large conventional generator that’s working hard can be just as efficient per kilowatt-hour, as DuroMax’s numbers show. The inverter’s advantage is biggest when the load is small, which is most of an outage.
Output and what you can connect
The portable inverters most people buy for home backup make about 1,800 to 4,000 running watts, and the ones in our catalog have 120-volt outlets only. That covers a fridge, freezer, sump pump, lights and a microwave, plugged in with heavy-duty outdoor cords. It does not cover a 240-volt well pump. Westinghouse’s iGen5000DFc offers 240 volts only through its optional parallel kit, and Champion’s 4500W inverter has a 30-amp RV outlet (TT-30R), which is 120 volts.
Conventional generators from about 7,500 watts up usually have a 120/240-volt L14-30R outlet, and many larger ones a 14-50R, ready for a transfer switch or interlock with an inlet box. That gear must be installed by a licensed electrician, with a permit where required, and never replaced by plugging the generator into a wall outlet (backfeeding), which FEMA and CPSC warn can kill utility workers. Small inverters can also be paired with a parallel kit to roughly double the power. See what size generator you need for the watt math.
Weight and size
Honda says building the alternator into the engine lets inverters be smaller and lighter, and small inverters are easy to carry: the Honda EU2200i weighs 47.4 pounds and the DuroMax XP2300iH 50.6. Watt for watt at home-backup sizes, though, the gap shrinks. Westinghouse’s inverter and conventional pair both weigh about 27 pounds per 1,000 running watts. At 100-plus pounds, plan on wheels and a second person to lift it.
Cost per watt
| Model | Type | Running watts (gas) | Price seen | Per running watt |
|---|---|---|---|---|
| Honda EU2200i | Inverter | 1,800 | $1,199 (Honda MSRP) | $0.67 |
| DuroMax XP2300iH | Inverter | 1,800 | $649 (duromaxpower.com) | $0.36 |
| Generac GP3300i | Inverter | 2,500 | $939 (Generac MSRP) | $0.38 |
| Westinghouse iGen5000DFc | Inverter | 3,900 | $1,299 (list) | $0.33 |
| Generac GP8000E | Conventional | 8,000 | $1,179 (Generac MSRP) | $0.15 |
| Westinghouse WGen7500DFc | Conventional | 7,500 | $1,299 (list) | $0.17 |
| DuroMax XP13000EH | Conventional | 10,500 | $1,299 (duromaxpower.com) | $0.12 |
Conventional power costs roughly half as much per watt. Big inverters do exist, but the price jumps: DuroMax listed its 13,500-watt XP13500iH dual fuel inverter at $2,699 on sale ($3,199 regular) in October 2026, about twice its conventional XP13000EH. If you can’t decide, many families pair a modest inverter for quiet nights with a battery or portable power station.
Safety is the same for both
A quiet inverter is still a gasoline engine making carbon monoxide. CPSC says nearly 100 people a year in the U.S. die from CO from portable generators. CPSC and CDC rules apply to both types:
- Outdoors only, at least 20 feet from the house, exhaust pointed away from windows, doors and vents.
- Never in a home, garage, basement, crawlspace, shed or porch, even with doors or windows open.
- Battery-powered or battery-backup CO alarms on every level of the home and outside bedrooms; test them.
- Buy a model with a CO shut-off: Honda CO-MINDER, Champion CO Shield, Generac COsense, Westinghouse CO Sensor, DuroMax CO Alert. CPSC points to models certified to PGMA G300-2023 and UL 2201-2023. A shut-off is a backup, not permission to run it closer.
- Let it cool before refueling; Ready.gov warns fuel spilled on a hot engine can ignite. Keep gasoline in approved cans away from the house, add stabilizer and rotate it.
Who should buy which
- Buy an inverter if you want a fridge, freezer, sump pump, lights, Wi-Fi and devices; you have close neighbors; you’ll also camp or tailgate; or you’ll run it for days and care about fuel.
- Buy a conventional generator if you have a 240-volt well pump, want many circuits on a transfer switch, or need the most watts for the money.
- Look at a standby generator or home battery if you need central air or the whole house; see whole-house generator cost and home battery vs generator.
Our picks of each type
Prices change often. The prices below are what we saw at the maker or a major retailer in October 2026; check the current price before you buy.
Honda EU2200i
- 1,800 W running / 2,200 W starting
- 48 dB(A) at 1/4 load, 47.4 lb
- CO-MINDER shut-off
DuroMax XP2300iH
- 1,800 W gas / 1,700 W propane
- Under 3% THD (maker)
- CO Alert, about $649 at DuroMax
Champion 4500W Dual Fuel Inverter
- 3,500 W running / 4,500 W starting (gas)
- 61 dB(A) at 23 ft
- CO Shield, electric start
Westinghouse iGen5000DFc
- 3,900 W running (gas), ≤3% THD
- Up to 18 h at 25% load
- CO Sensor shut-off
Westinghouse WGen7500DFc
- 7,500 W running / 9,500 W starting (gas)
- 120/240V L14-30R
- CO Sensor shut-off
DuroMax XP13000EH
- 10,500 W gas / 10,000 W propane running
- L14-30R and 14-50R outlets
- CO sensor shutdown, about $1,299 at DuroMax
Kidde 30CUD10-V Smoke + CO Alarm
- Sealed 10-year battery
- Voice alerts for fire and CO
- 10-year limited warranty
The Honda EU2200i is the quiet benchmark, at about $1,199 (Honda MSRP, October 2026). The DuroMax XP2300iH does the same job on gas or propane for about $649 on DuroMax’s site. For a home on a well, the Westinghouse WGen7500DFc’s L14-30R outlet is made for a transfer switch.
Check the Champion 4500W Dual Fuel Inverter price on Amazon
Check the Westinghouse WGen7500DFc price on Amazon
Keep exploring
Our home generators hub covers every type. For picks, see the best inverter generators, dual fuel generators and generators for a power outage; for hookups, the transfer switch guide; for safety, how to run a generator safely. Want no engine at all? Compare power station vs generator and home battery backup. Fuel basics live on our petroleum and propane pages, and every generator article is in the generators category.
Inverter vs conventional questions
Is an inverter generator better for a house?
For essentials, usually yes: it’s quieter, sips fuel at light loads and makes clean power for electronics. For a house with a 240-volt well pump or many circuits on a transfer switch, a conventional generator around 7,500 watts gives you the watts and the 240-volt outlet for about the same price as a 4,000-watt inverter.
Can a conventional generator damage electronics?
Makers of under-3% THD inverters say they are safe for sensitive electronics; Westinghouse rates its conventional WGen models at up to 23% THD. Many devices tolerate that, but some don’t, and makers rarely promise. Put computers and TV gear on a UPS or power station between the generator and the device, and check appliance manuals.
How much quieter is an inverter generator?
Champion measures both of its types at 23 feet: 61 dB(A) for its 4500W inverter and 74 dB(A) for its 9200W open-frame. NIH says each 10 dB sounds about twice as loud, so the open-frame sounds more than twice as loud. Compare figures only when the maker states the same distance.
Do inverter generators use less gas?
At light loads, yes. Honda says Eco Throttle cuts fuel use by up to 40% because the engine slows down. From Westinghouse’s figures, its inverter burns about 0.19 gallons an hour at 25% load, its conventional 7,500-watt model about 0.6. Under heavy loads the difference narrows.
Can I connect an inverter generator to a transfer switch?
Sometimes. Most small inverters are 120 volts only, so they can’t feed 240-volt circuits. Some, like the Westinghouse iGen5000DFc with its parallel kit, gain a 240-volt outlet. The switch or interlock and inlet must match the generator’s outlet and your panel, and a licensed electrician should install them, with a permit where required.